Heavy duty smart switch 40A Z-Wave module
AC & Heaters
Aeotec

Aeotec Heavy Duty Switch

Product code 0081
Sh 400,000.00
In stock in Dar es Salaam

In stock

Ask about this on WhatsApp
  • Genuine stock. Sourced from authorised distributors, warranty intact.
  • Delivered across Tanzania with additional delivery charges.
  • Multiple payment options.
Payment Options
  • Cash on Delivery. You can pay cash at our store on pickup, or pay the rider upon delivery (Dar es Salaam only).
  • Pay by Lipa Number
    • M-Pesa
    • Mixx by Yas
    • Airtel Money
    • Halopesa
    • Selcom
  • Pay by Card
    • Visa
    • Mastercard
    • American Express
    • Discover
    • UnionPay
  • Pay by Apple Pay or Google Pay
    • Apple Pay
    • Google Pay
40 A Maximum current
9,600 W At 240 V
868.42 MHz Z-Wave Plus, EU band
kWh Energy monitoring built in
1 W Standby draw

About this product

A heavy duty smart switch is what you reach for when the thing you want to switch is too big for an ordinary one. A borehole pump, a three-phase-fed water heater, a large geyser, a workshop compressor: loads where a normal glass touch panel would be well outside its rating. The Aeotec Heavy Duty Switch is rated to 40 amps, which is 9,600 watts at 240 volts, and it is built as a hard-wired module with heavy screw terminals rather than a wall plate.

It also measures. As well as switching the load it reports real-time power in watts and cumulative energy in kilowatt hours back to your controller, so you can see what the pump or the geyser is actually costing you rather than guessing. On a property where the water heater is the biggest single line on the bill, that is usually the more interesting half of the product.

It is a Z-Wave device, so it needs a Z-Wave hub. It has no Wi-Fi and no app of its own. Ours is the EU variant, ZW078-C, which runs on 868.42 MHz, and your hub has to be on the same band. A hub bought in the United States runs on 908.42 MHz and will never see it.

Two more things worth saying plainly. It is rated IP44 but Aeotec's own documentation specifies indoor use only, so an outdoor pump housing needs its own weatherproof enclosure around it. And it is not a plug-in device: it terminates heavy cable on screw terminals and belongs to an electrician, not a weekend.

Loads a heavy duty smart switch is for

A borehole pump, a large geyser, a workshop compressor: loads where a glass touch panel would be well outside its rating. A heavy duty smart switch of this kind is built as a hard-wired module with heavy screw terminals rather than a wall plate, rated to 40 A resistive, which is 9,600 W at 240 V, and up to 5 HP of motor load.

Peak current endurance is 1,440 A for 10 ms, which is the figure that matters when a pump motor starts.

It measures as well as switches

As well as switching the load it reports real-time power in watts and cumulative energy in kilowatt hours back to your controller. On a property where the water heater or the borehole pump is the biggest single line on the bill, that is usually the more interesting half of the product: you stop guessing what a circuit costs and start reading it.

It needs a Z-Wave hub, on the right band

It is a Z-Wave Plus device. It has no Wi-Fi and no app of its own, so a Z-Wave controller is required.

Ours is the EU variant, ZW078-C, running on 868.42 MHz, and your hub has to be on the same band. A hub bought in the United States runs on 908.42 MHz and will never see it. That is not a setting, it is a different radio, so check the hub before you order.

Two things to plan around

It is rated IP44, but Aeotec own documentation specifies indoor use only. An outdoor pump housing therefore needs its own weatherproof enclosure built around it rather than relying on the module rating.

And it is not a plug-in device. It terminates heavy cable on screw terminals, draws 1 W on standby, weighs 428 g and works from 5 to 40 degrees C. This belongs to an electrician rather than to a weekend.

Check your hub band first

The one thing that will waste your money here is a controller on the wrong frequency. Ours is the EU unit on 868.42 MHz. A hub carried back from the United States runs on 908.42 and the two will never meet. Tell us what you are running and we will confirm the pair before anything ships.

Beyond that it is an electrician job, and on an outdoor pump it needs its own weatherproof box around it. Aeotec keep the manual at aeotec.com. See also AC and heaters.

Description supplied by the manufacturer.

Specifications

ModelAeotec Heavy Duty Smart Switch Gen5, ZW078-C (EU variant)
ProtocolZ-Wave Plus
Frequency868.42 MHz. Your hub must be on the same band.
Maximum current40 A resistive
Maximum load9,600 W at 240 V
Motor loadUp to 5 HP at 240 V AC
Peak current endurance1,440 A for 10 ms
Supply240 V AC, 50/60 Hz
Energy monitoringReal-time watts and cumulative kilowatt hours
Standby consumption1 W
Weather ratingIP44, but specified by Aeotec for indoor use only
Operating temperature5 to 40 °C
Radio rangeUp to 150 m outdoors, line of sight
Weight428 g
Hub requiredYes. Any Z-Wave Plus controller on the 868.42 MHz band.
InstallationHard wired to screw terminals. Electrician required.
Product code0081
CategoryAC & Heaters
AvailabilityIn stock in Dar es Salaam

What’s in the box

  • Heavy Duty Smart Switch Gen5
  • 8 AWG wire terminals
  • 10 AWG wire terminals
  • Screws
  • Instruction manual

Questions

Do I need a hub?

Yes. This is Z-Wave, not Wi-Fi, and it has no app of its own. You need a Z-Wave hub, and it must be on the 868.42 MHz European band, which is what this unit uses. A hub brought from the United States runs on 908.42 MHz and will not see it at all. Ask us if you are not sure what your hub is.

What can it actually switch?

The heavy things. Rated to 40 amps, which is 9,600 watts at 240 volts, and up to a 5 horsepower motor. Borehole and pool pumps, large geysers, workshop machinery. It is meant for the loads that are too big for a wall switch.

Can it go outside next to the pump?

Not on its own. It is rated IP44 but Aeotec specify it for indoor use, so outdoors it needs to sit inside its own weatherproof enclosure. Plenty of installations do exactly that, but the enclosure is not optional and it is not included.

Does it tell me how much power I am using?

Yes, and this is half the point of it. It reports live power draw in watts and running totals in kilowatt hours to your hub. If you want to know what the geyser or the pump is really adding to the bill, this measures it rather than estimating.

Can I fit it myself?

No. It is hard wired, it takes heavy gauge cable on screw terminals, and it sits on a circuit carrying up to 40 amps. This is an electrician's job. Ask us and we can point you to someone who has fitted them before.

Anything else? Ask us on WhatsApp and we will tell you straight.

From the same shelf

You might also want

All AC & Heaters →